  Datasheet File OCR Text:
  for more information, please visit the product page. ????????? ?????????????????? cui .com 02/23/2017 1 of 5 series : PSK-6B description: ac-dc power supply model output voltage output current output power ripple and noise 1 effciency (vdc) max (a) max (w) typ (mvp-p) typ (%) PSK-6B-s5 5 1.2 6 100 75.18 PSK-6B-s9 9 0.67 6 100 79.03 PSK-6B-s12 12 0.5 6 120 79.03 PSK-6B-s15 15 0.4 6 150 79.03 PSK-6B-s24 24 0.25 6 240 79.03 notes: 1. at full load, nominal input, 20 mhz bandwidth oscilloscope, output terminated with 10 f electrolytic and 0.1 f ceramic capacitors. 2. all specifcations are measured at ta=25c, nominal input voltage, and 75% rated output load unless otherwise specifed. features ? up to 6 w continuous power ? universal input: 85~264 vac ? compact encapsulated design ? single output from 5 vdc ~ 24 vdc ? short circuit, over voltage protection, over current protection ? 4000 vac isolation ? no load power consumption <100 mw part number key base number PSK-6B - s xx output voltage date page
for more information, please visit the product page. ?????????????????? cui .com date 02/23/2017 page 2 of 5 cui inc series : PSK-6B description: ac-dc power supply input parameter conditions/description min typ max units voltage 85 120 264 370 vac vdc frequency 47 63 hz current 0.25 a inrush current at 240 vac, 25c, cold start 40 a leakage current 0.25 ma no load power consumption 0.10 w output parameter conditions/description min typ max units capacitive load 5 vdc output model 9 vdc output model 12 vdc output model 15 vdc output model 24 vdc output model 1,200 670 500 400 200 f f f f f initial set point accuracy at full load, 25c 5, 9 vdc output models 12 vdc output model 15, 24 vdc output models 5 4 3 % % % line regulation high line to low line at full load 1 % load regulation 10%~100% load 5, 9 vdc output models 12 vdc output model 15, 24 vdc output models 5 4 3 % % % hold-up time at 115 vac 12 ms switching frequency 30 70 khz temperature coeffcient 0.05 %/c protections parameter conditions/description min typ max units over current protection 110 % short circuit protection hiccup, auto recovery safety & compliance parameter conditions/description min typ max units isolation voltage input to output 4,000 vac safety approvals iec62368-1/60950-1, en62368-1/60950-1, ul62368-1/60950-1 safety class class ii emi/emc en 55032 class b, fcc part 15 class b, en 61000- 6-3, en 61000-3-2, en 61000-3-3, en 55024, en 61204-3, en 61000-6-1 mtbf as per mil-hdbk-217f, at 115 vac, 25c, gb 300,000 hours life time at 40c, 75% load 3 years rohs 2011/65/eu environmental parameter conditions/description min typ max units operating temperature see derating curve -25 70 c storage temperature -40 85 c operating humidity non-condensing 93 % operating altitude 3000 m
for more information, please visit the product page. ?????????????????? cui .com date 02/23/2017 page 3 of 5 cui inc series : PSK-6B description: ac-dc power supply solderability parameter conditions/description min typ max units wave soldering see wave soldering profle 260 c t emperature ( c) t ime (seconds) notes: 1. soldering materials: sn/cu/ni 2. ramp up rate during preheat: 1.4c/s (from 50c to 100c) 3. soaking temperature: 0.5c/s (from 100c to 130c), 6020 seconds 4. peak temperature: 260c, above 250c for 3~6 seconds 5. ramp down rate during cooling: -10c/s (from 260c to 150c) mechanical parameter conditions/description min typ max units dimensions 2.000 x 1.000 x 0.659 (50.80 x 25.40 x 16.74 mm) inch weight 36 g cooling natural convection mechanical drawing pin connections pin function 1 acn 2 acl 3 +vout 4 -vout 3 4 2 1 45.7 2 0.80 0 1.80 0 10.1 6 0.40 0 20.3 2 50.8 0 2.00 0 2.54 0.10 0 1.00 0 25.4 0 1.00 0.65 9 16.7 4 0.03 9 0.23 66 .0 0 units: inch [mm] tolerance: x.xxx = 0.020 [0.50]
for more information, please visit the product page. ?????????????????? cui .com date 02/23/2017 page 4 of 5 cui inc series : PSK-6B description: ac-dc power supply derating curve output power vs. ambient temperature (natural convention) ambient t emper ature (c) load (% ) -25 50 75 100 25 -15 15 45 65 -5 52 53 55 57 5 0 0 efficiency curves 5 vdc output effciency curve (at 25c) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 10 current load (% ) efficiency (% ) 85 vac 115 vac 230 vac 264 vac 20 30 40 50 60 70 80 90 100 9 vdc output effciency curve (at 25c) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 90.0 efficiency (% ) 85 vac 115 vac 230 vac 264 vac 10 current load (% ) 20 30 40 50 60 70 80 90 100 12 vdc output effciency curve (at 25c) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 efficiency (% ) 85 vac 115 vac 230 vac 264 vac 10 current load (% ) 20 30 40 50 60 70 80 90 100 15 vdc output effciency curve (at 25c) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 efficiency (% ) 85 vac 115 vac 230 vac 264 vac 10 current load (% ) 20 30 40 50 60 70 80 90 100 24 vdc output effciency curve (at 25c) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 efficiency (% ) 85 vac 115 vac 230 vac 264 vac 10 current load (% ) 20 30 40 50 60 70 80 90 100
for more information, please visit the product page. ????????? date 02/23/2017 page 5 of 5 cui inc series : PSK-6B description: ac-dc power supply cui offers a two (2) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to be accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use. cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 02/23/2017 the revision history provided is for informational purposes only and is believed to be accurate. revision history